FEPS Series Emergency Power Supply 0.5KVA-10KVA

FEPS series products features and application fields

FEPS series BK11 small power and BK33 medium, high power FEPS, the capacity is from 0.5KVA to 500KVA, This series products adopts high-speed MCU and CPLD, controlled by Software Programming. The power devices adopt the most advanced sixth generation low losses high power IGBT and static switch. The series products is the power supply products with international newest control devices and the advanced software, is a dedicated power supply which is applied to fire emergency equipments.

FEPS series single/three phase intelligent digital EPS

FEPS series products features and application fields
FEPS series BK11 small power and BK33 medium, high power FEPS, the capacity is from 0.5KVA to 500KVA, This series products adopts high-speed MCU and CPLD, controlled by Software Programming. The power devices adopt the most advanced sixth generation low losses high power IGBT and static switch. The series products is the power supply products with international newest control devices and the advanced software, is a dedicated power supply which is applied to fire emergency equipments.

EPS-jpg01

Main features

1. Screen cabinet design, intuitionistic big screen LCD with Chinese, English display, LED status indication
2. The flow diagram running status visual display, intelligent icon touch button, tabular data display, events records display, Chinese and English optional menu operation
3. Inverter back-up work mode design, high speed static transfer switch
4. Intelligent digital control technology
Realize circuit control, parameters settings, running management, advanced self-check and self-detection function via adopting three pieces high speed MCU and CPLD, also self check all independent circuit connections of PCB boards and faults analysis. Via sine wave voltage of digital conversion, we can assure systems overstable running. Perfect new projects can meet our customers’ actual demand.

EPS-jpg02

5. High-efficiency IGBT(Insulated Gate Bipolar Transistor)inverter technology
IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power.

6. Excellent load feature
It completely meet load step from 0-100% while no need change to bypass, and make sure the output stable, reliable

7. Perfect protection function
Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function.

8. High-powered dynamic feature
Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only realize the high dynamic adjustment, but also reduce the output voltage distortion.

9. Adopt 6 pulse rectifier charger, Intelligent battery management
Intelligent battery charge: automatically set the battery charge current parameter according to the battery capacity, and also reach the boost and float voltage transformation, temperature compensation and discharge management. Prolong the battery lifetime and reduce the administrator’s burden.

10. Selectable battery inspection module
Can measure single parameter and display on the LCD, Battery failure will immediately alarm and inform the administrator.

11. Intelligent detecting function
This system microprocessor can continually online detect power status, the breaker status and all the working status. Like meeting the faults, EPS immediately protect, alarm and notice the administrator.

12. Intelligent communication interface
With RS232 and RS485 standard collocation, optional SNMP, selectable dry connector, adopt non-source contactor to reach the monitor of the EPS.

BK11 series small power FEPS single phase emergency power supply main technology parameters

Model

0.5KVA

1KVA

1.5KVA

2KVA

2.5KVA

3KVA

3.7KVA

4KVA

5KVA

6KVA

7KVA

8KVA

9KVA

10KVA

Nominal Capacity(KVA)

0.5

1

1.5

2

2.5

3

3.7

4

5

6

7

8

9

10

Input voltage, frequency

165~242VAC,50Hz±5%

Emergency output voltage, frequency

220V±3%,50Hz±0.5%

Emergency output wave form

sine wave, distortion factor<3%(linear load)

Dynamic characteristics

Dynamic transient range <±10%(from 0 to100% ), transient recover time<20mS

Overload Protection

over load 120% normal running, over load 150%  immediately protect  

Transfer Time

<1ms(Static Switch, switch), the biggest time<5s, can manually transfer

Efficiency

emergency power supply>90%, main power supply ~closed to 100%

transfer function

manual and automatic transfer function

Linkage control function

External access 24 V linkage control signal, turn to emergency power supply mode

Mandatory start

start mandatory start switch, work in the emergency mode, meantime close battery low voltage protection

protection

output short circuit/overload/over voltage, low voltge/ over temperature etc. protections, Default Phase can run, with Audible and visual alarm.

display

LED display: Mains indicate (Green), Emergency indicate (Red), charge indicate(Red) and faults indicate(yellow)

LCD display: input/output voltage, output current, inverter voltage, frequency, output current, battery pack voltage, temperature work mode, flow diagram, current work status, events records and systems information etc.

Alarm

Imitate mains faults, battery low voltage, temperature faults, breakers break off etc.faults, check voice alarm(mute silence function) and status indicate

Running environment

Temperature -25℃~55℃

Relative humidity

0~90%

charge function

basically complete to battery charge in 24 hours and again discharge, it reach above rated time *80%

insulated Resistance

input/output to ground insulated Resistance >=5MΩ

withstand voltage

Between input/output and shell withstand frequency 50*(1+-0.01)Hz, voltage 1250*(1+-0.1)V for 60s+-5s, shouldn’t happen surface fly arc or breakdown phenomenon

leakage current

When 1.06 times nominal voltage works, the leakage current<=0.5mA

Battery type

Maintenance-free sealed acid battery

nominal battery voltage

48VDC

192VDC

charge voltage

55VDC

220VDC (automatically Equalized Charging once every 3 months, charge voltage 232VDC)

battery low voltage protection

43.2VDC

172.8 VDC

discharge time

90min

battery static  discharge

static discharge current<=10-5C20A

Computer Communication Interface

RS232/RS485

Cooling down method

COMPULSIVE VENTILATION

Noise(dB)

(according to load and temperature) 1M away from the machine

40~60

 Size

W×D×H(Unit:mm)

600×250×880

600×620×1250

weight(kg)

60

63

68

70

75

77

78

79

80

83

168

169

170

171

BK33 series medium, high power FEPS three phase emergency power supply main technology parameters

 Mode

3KVA

6KVA

8KVA

10KVA

15KVA

18.5KVA

22KVA

30KVA

37KVA

45KVA

50KVA

55KVA

75KVA

80KVA

90KVA

100KVA

110KVA

Input voltage, frequency

phase voltage 165~242VAC, Line voltage 323~418v, 50Hz+-5%

Emergency output voltage, frequency

phase voltage 220V+-3%, Line voltage 380V+-3%, 50Hz±0.5%

Emergency output wave form

sine wave, distortion factor<3%(linear load)

Dynamic characteristics

Dynamic transient range <±10%, transient recover time<20mS

Overload Protection

over load 120% normal running, over load 150%  immediately protect  

Transfer Time

<0.1s(Static Switch, switch), the biggest time<5s, can manually transfer

Efficiency

Emergency power supply>90%, main power supply ~closed to 100%

transfer function

manual and automatic transfer function

Mandatory start

start mandatory start switch, work in the emergency mode, meantime close battery low voltage protection

Display

LED display: Mains indicate (Green), Emergency indicate (Red), charge indicate(Red) and faults indicate(yellow)

LCD display: input/output voltage, output current, inverter voltage, frequency, output current, battery pack voltage, temperature work mode, flow diagram, current work status, events records and systems information etc.

Running environment

Temperature -25℃~55℃

Relative humidity

0~90%

charge function

basically complete to battery charge in 24 hours and again discharge, it reach above rated time *80%

insulated Resistance

input/output to ground insulated Resistance >=5MΩ

withstand voltage

Between input/output and shell withstand frequency 50*(1+-0.01)Hz, voltage 1250*(1+-0.1)V for 60s+-5s, shouldn’t happen surface fly arc or breakdown phenomenon

leakage current

When 1.06 times nominal voltage works, the leakage current<=0.5mA

Battery type

maintenance-free sealed acid battery

 nominal battery voltage

192VDC

384VDC (32pcs 12V batteries)

 battery static  discharge

 static discharge current<=10-5C20A

 charge voltage

216VDC

432VDC

Battery low voltage protection

168VDC

336VDC

 discharge time

>3H

Computer Communication Interface

RS232/RS485

Cooling down method

COMPULSIVE VENTILATION

    noise (dB)

 (according to load and temperature) 1M away from the machine

40~50

50~55

55~65

 Size

W*D*H(Unit:mm)

600*620*1250

600*720*1550

980*800*1800

Weight(kg)

164

172

189

197

243

262

281

308

378

431

449

450

760

772

821

837

850

Request a quote